| Test Name | Test Method | Lead Time | Yardage | |
|---|---|---|---|---|
| British Drapery | BS 5867 Part 2, Type B | 1-2 days | 36" x Full | |
| British Drapery | BS 5867 Part 2, Type C | 1-2 days | 36" x Full | |
| British Protective Clothing | BS EN ISO 15025 | 1-2 days | 36" x Full | |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Part 1 | |||
| Smoldering Cigarette (Source 0) | BS 5852/7176 | 3-4 days | 54" x Full |
| Butane Flame (Source 1) | BS 5852/7176 | 3-4 days | 54" x Full |
| Part 2 | |||
| Butane Flame (Source 2) | BS 5852/7176 | 3-4 days | 54" x Full |
| Butane Flame (Source 3) | BS 5852/7176 | 3-4 days | 54" x Full |
| Crib Ignition (Source 4) | BS 5852/7176 | 3-4 days | 54" x Full |
| Crib Ignition (Source 5) | BS 5852/7176 | 3-4 days | 54" x Full |
| Crib Ignition (Source 6) | BS 5852/7176 | 3-4 days | 54" x Full |
| Crib Ignition (Source 7) | BS 5852/7176 | 3-4 days | 54" x Full |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Small Scale | CAN/ULC S109 | 1-2 days | 18" x Full |
| Large Scale (Folds) | CAN/ULC S109 | 1-2 days | 3 yds x Full |
| Large Scale (Flat) | CAN/ULC S109 | 1-2 days | 3 yds x Full |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Mattress Prototype Testing (2 tests) | 16 CFR 1632 | 3-4 days | 2 sleeping surfaces |
| Mattress Pads Prototype Testing (6 tests) | 16 CFR 1632 | 3-4 days | 6 mattress pads |
| Mattress Ticking Prototype Testing | 16 CFR 1632 | 2-3 days | 36" x Full |
| Business & Institutional Furniture Manufacturer's Association | 2-3 days | 36" x Full | |
| California Technical Bulletin #116 | 2-3 days | 2 samples | |
| California Technical Bulletin #117 | |||
| Section 1: Cover Fabric Test | 1-2 days | 18" x Full | |
| Section 2: Barrier Materials Test | 1-2 days | 18" x Full | |
| Section 3: Resilient Material Test | 1-2 days | ||
| Section 4: Decking Material Test | 1-2 days | 36" x 18" | |
| UFAC/NFPA 260 | |||
| Fabric Classification | UFAC/NFPA 260 | 1-2 days | 18" x Full |
| Welt Cord | UFAC/NFPA 260 | 1-2 days | 1 yrd |
| Decking Materials | UFAC/NFPA 260 | 1-2 days | 18" x 18" |
| Filling/Padding Component | UFAC/NFPA 260 | 1-2 days | |
| Barrier | UFAC/NFPA 260 | 1-2 days | 24" x 24" |
| Interior Fabrics | UFAC/NFPA 260 | 1-2 days | 18" x Full |
| Decorative Trim | UFAC/NFPA 260 | 1-2 days | 36" x Full |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Flammability of Interior Materials (Cars, Trucks, Multi-Purpose Passenger Vehicle, Busses) | FMVSS302 CMVSS302 | 1-2 days 1-2 days | 18" x Full 18" x Full |
| Federal Aviation Administration | FAR 23.853/25.853 | 1-2 days | 18" x Full |
| Carpets & Rugs | 16 CFR 1630/1631 | 3-4 days | 18" x 36" |
| Sleeping Bags | CPAI-75 | 2-3 days | 2 bags |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Smoldering Cigarette | IMO 652 (16) | 3-5 days | 54" x Full |
| Butane Flame | IMO 652 (16) | 3-5 days | 54" x Full |
| Drapery Material | IMO 2010 FTP Code, Part 7 | 1-2 days | 36" x Full |
| Upholstery | IMO 2010 FTP Code, Part 8 | 3-5 days | 54" x Full |
| Bedding | IMO 2010 FTP Code, Part 9 | 3-5 days | 54" x Full |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Flame Resistance of Cloth | ASTM D6413 | 1-2 days | 18” x Full |
| Flame Resistance of Cloth | FSTM-191-5903 | 1-2 days | 18” x Full |
| Boston Fire Dept. | BFD IX-1 | 1-2 days | 18” x Full |
| New York City | New York Bulletin No. 44 | 1-2 days | 18” x Full |
| California Title 19 (Indoor Materials) | State of California, 1237 | 1-2 days | 18” x Full |
| California Title 19 (Outdoor Materials) | State of California, 1237 | 7-10 days | 54” x Full |
| Federal Aviation Administration | FAR 23.854/25.653 | 1-2 days | 18” x Full |
| National Fire Protection Association | NFPA 701-89 Small Scale | 1-2 days | 18” x Full |
| National Fire Protection Association | NFPA 701 Test 1 | 1-2 days | 36” x Full |
| National Fire Protection Association | 1-2 days | ||
| Folds | NFPA 701 Test 2 | 1-2 days | 3 yds x Full |
| Strips | NFPA 701 Test 2 | 1-2 days | 3 yds x Full |
| Field Test | NFPA 705 | 1-2 days | 12" x 12" |
| Camping Tentage (Wall Material) | CPAI-84 | Original 1-2 days Full 7-10 days | 18” x Full 54” x Full |
| Camping Tentage (Flooring Material) | CPAI-84 | Original 1-2 days Full 7-10 days | 18” x Full 54” x Full |
| Children's Sleepwear | 16 CFR 1615/1616 | 2-3 days | 18” x Full |
| Seams/Trim (Prototype) | 17 CFR 1615/1616 | 2-3 days | |
| Garment Production | 18 CFR 1615/1616 | 2-3 days |
| Test Name | Test Method | Lead Time | Yardage |
|---|---|---|---|
| Flammability of Wearing Apparel | NFPA 702 (original & after) | 2-3 days | 18" x Full |
| Flammability of Apparel Textiles | ASTM D-1230 (original & after) | 2-3 days | 18" x Full |
| Flammability of Clothing Textiles | 16 CFR Part 1610 (original only) | 1-2 days | 12" x Full |
| Flammability of Clothing Textiles | 16 CFR Part 1610 (original & after) | 2-3 days | 24" x Full |
| Textile Flammability Regulations (Canada Consumer Product Safety Act) | CAN/CGSB 4.2 No. 27.5-2014 (SOR/2016-194) | 1-2 days | 12" x Full |